logo
Products
PRODUCTS DETAILS
Home > Products >
Pharmaceutical Bio Waste Disposal Machine Shredder Treatment System OEM

Pharmaceutical Bio Waste Disposal Machine Shredder Treatment System OEM

MOQ: 1
Delivery Period: 45 work days
Payment Method: ,T/T,L/C
Supply Capacity: 10 units monthly
Detail Information
Place of Origin
CHINA
Brand Name
Li-Ying Technology
Certification
CE, ISO
Model Number
MDU-10
Equipment Model No.:
MDU-10
Dimensions (L*W*H):
12,000mm*2,900mm*3,300mm
Overall Weight:
15,000kg
Required Space (L*W*H):
15,000mm*5,000mm*5,600mm
Installed Power:
170KW (108KW Steam Generator Included)
Highlight:

Pharmaceutical bio waste disposal machine

,

bio waste disposal machine Shredder

,

OEM pharma waste shredder machine

Product Description
MDU-10

MDU-10 is a medical waste integration treatment system including auto-feeding, shredding, microwave sterilization, auto-discharging, and exhaust dedusting systems.

Specifications:
  • Treatment capacity: 600kg/h (±10%)
  • Dimensions (L*W*H): 12000mm*2900mm*3300mm
  • Overall weight: 15000kg
  • Required space (L*W*H): 15000*5000*5600mm
  • Installed Power: 170KW (108KW steam generator included)
Introduction

MDU-type medical waste steam microwave sterilization equipment is used for the harmless disposal of medical waste. The scope of disposal is medical waste that is classified as infectious, traumatic, and pathological waste (except for human limbs and organs). It can also be used in epidemics When dealing with sick and dead poultry.

Microwave sterilization unit for medical waste Model MDU-10

MDU-10 is an integration system including feeding, shredding, sterilization, discharging, and exhaust dedusting systems.

600kg/h or 6000l/h treatment capacity, based on an average density of medicalwaste at 0.1kg/l ~0.15kg/l.

The equipment operating UI and the entire Med waste IoT monitoring system are developed by our professional software team. As so, we are able to quickly develop customised UI systems in any language.

It can service well to cities with 3 million of people, you can choose it if you are a institute providing medical waste collection and central treatment to local hospitals, clinics, etc. with any other healthcare center for cities or regions with a population about 3 million.

Specifications
Equipment Model No. MDU-10
Dimensions (L*W*H) 12,000mm*2,900mm*3,300mm
Overall weight 15,000kg
Required space (L*W*H) 15,000mm*5,000mm*5,600mm
Installed Power 170KW (108KW steam generator included)
Process
  1. The infectious material is temporarily held in a waste container(s) which in turn, are emptied into an pre storage hopper via a charging system which is located at the front of the MDU.
  2. The infectious waste is fed to the shredding system by a feed arm where it is shredded.
  3. The shredded material is conveyed through a microwave section and temperature holding section, respectively for sterilization, with microwave of 2450MHz (±50MHz), temperature ≥95℃, with over 45minutes. (High pressure High temperature special type MDU will be a slightly different.)
  4. The sterilized and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor.
  5. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.
How does the Medical Waste Microwave Sterilization Unit (MDU) perform microwave sterilization?

Microwave sterilization is the result of microwave thermal effect and biological effect, which can make microwave energy and bacteria directly interact, rapid sterilization.

The thermal effect of microwave energy: Under certain intensity microwave field, the bacteria will be due to the absorption of polarized molecules can increase the temperature of microwave, so that the protein deformation, loss of biological activity. The thermal effect of microwave mainly plays the role of rapid temperature sterilization.

Non-thermal effects of microwave energy: High-frequency electric fields change the polarized molecular structure, resulting in the loss of vitality or death of proteins and physiologically active substances in the microbes, and the special effects of conventional physical sterilization in the sterilization

Applicable Range
  • Blood and Blood Products
  • Dialysis Waste
  • Animal Tissues, Body Parts, and Carcasses
  • Human Tissues, Body Parts, and Limbs
  • Biological and Non-Hazardous Pharmaceutical
  • Needles, Syringes, and other Sharps
  • Research Waste
  • Laboratory Specimens
  • Surgery Waste
  • Pathology and Histology Samples
  • Aids and Hepatitis Waste
  • Isolation Waste
  • Cultures and Slides
  • Intravenous Bags, Blood Bags, and Associated Tubing
  • Animal Bedding
  • Packaging Materials
  • Gloves, and Gowns Associated with Waste Collection
  • Trace Chemotherapy/anti- neo plastic waste
Technical Characteristics
  • 01 Energy saving

    Microwave heating is uniform, no energy loss, high energy, strong penetration into the object, instantaneous penetration into the object, good energy-saving effect, take the model with a daily processing capacity of 5T/d as an example, installed power Only 117 kilowatts.

  • 02 Efficient energy

    The temperature of action is low, and the heat loss is slow: If microwave and ordinary heating produce the same amount of sterilization, the temperature of the object will be significantly lower than that of ordinary heating. The waste after microwave sterilization is non-toxic, without residue, and lightly damaged.

  • 03 Absolute sterilization and disinfection

    Microwave can effectively sterilize all materials on all organisms with no select. It has a broad spectrum of sterilization bacteria and can kill various microorganisms and pathogens.

  • 04 Spatial convenience

    Microwave sterilization requires a small working environment and small area, does not cause high temperature to the surrounding environment, and is clean and hygienic.

  • 05 Environmental friendly

    No acid gas and dioxins and other pollutants are produced.

Equipment Advantages
  • The equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.
  • Low energy consumption, the whole set of equipment only needs electric drive, taking 5t per day as an example, the total installed power is only 117 kilowatts.
  • The medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.
  • There are two types of microwave sterilization equipment: fixed and mobile.
Technical Compare
Compare technologies LiYing Technology Autoclave Autoclave with a shedder Incinerator
  (Microwave) (Hot steam) (Hot steam) (Incineration)
Continuous process X X X
Integral shredding X X
Unrecognisable waste X
Volume of waste reduction X
Mass of waste reduction X X
Installation requirements Low High High High
Complexity of the installation Low Intermediate Intermediate High
On-site installable X
Technology approval by countries all over the world High Intermediate High Low
Level of sterelization High Intermediate High High
Odours Low High Intermediate Intermediate
Noise Low Intermediate Intermediate High
Treatment of pathological and anatomical waste X
Cost
ROI High Low Low Low
Investment costs Intermediate Low Intermediate High
Operating costs Low High High High
Maintenance costs Low High High High
Labour costs Low High High High
Environment
Impacts on the environment Low Intermediate Intermediate High
Treated waste recyclable X X X
No contaminated rejection (such as water, steam) X X X
Security
No risk related to pressurized vessel X X X
Risk for workforce/personnel health No risk of toxic contaminants released into the air or the treated waste Intermediate Intermediate High
Products
PRODUCTS DETAILS
Pharmaceutical Bio Waste Disposal Machine Shredder Treatment System OEM
MOQ: 1
Delivery Period: 45 work days
Payment Method: ,T/T,L/C
Supply Capacity: 10 units monthly
Detail Information
Place of Origin
CHINA
Brand Name
Li-Ying Technology
Certification
CE, ISO
Model Number
MDU-10
Equipment Model No.:
MDU-10
Dimensions (L*W*H):
12,000mm*2,900mm*3,300mm
Overall Weight:
15,000kg
Required Space (L*W*H):
15,000mm*5,000mm*5,600mm
Installed Power:
170KW (108KW Steam Generator Included)
Minimum Order Quantity:
1
Delivery Time:
45 work days
Payment Terms:
,T/T,L/C
Supply Ability:
10 units monthly
Highlight

Pharmaceutical bio waste disposal machine

,

bio waste disposal machine Shredder

,

OEM pharma waste shredder machine

Product Description
MDU-10

MDU-10 is a medical waste integration treatment system including auto-feeding, shredding, microwave sterilization, auto-discharging, and exhaust dedusting systems.

Specifications:
  • Treatment capacity: 600kg/h (±10%)
  • Dimensions (L*W*H): 12000mm*2900mm*3300mm
  • Overall weight: 15000kg
  • Required space (L*W*H): 15000*5000*5600mm
  • Installed Power: 170KW (108KW steam generator included)
Introduction

MDU-type medical waste steam microwave sterilization equipment is used for the harmless disposal of medical waste. The scope of disposal is medical waste that is classified as infectious, traumatic, and pathological waste (except for human limbs and organs). It can also be used in epidemics When dealing with sick and dead poultry.

Microwave sterilization unit for medical waste Model MDU-10

MDU-10 is an integration system including feeding, shredding, sterilization, discharging, and exhaust dedusting systems.

600kg/h or 6000l/h treatment capacity, based on an average density of medicalwaste at 0.1kg/l ~0.15kg/l.

The equipment operating UI and the entire Med waste IoT monitoring system are developed by our professional software team. As so, we are able to quickly develop customised UI systems in any language.

It can service well to cities with 3 million of people, you can choose it if you are a institute providing medical waste collection and central treatment to local hospitals, clinics, etc. with any other healthcare center for cities or regions with a population about 3 million.

Specifications
Equipment Model No. MDU-10
Dimensions (L*W*H) 12,000mm*2,900mm*3,300mm
Overall weight 15,000kg
Required space (L*W*H) 15,000mm*5,000mm*5,600mm
Installed Power 170KW (108KW steam generator included)
Process
  1. The infectious material is temporarily held in a waste container(s) which in turn, are emptied into an pre storage hopper via a charging system which is located at the front of the MDU.
  2. The infectious waste is fed to the shredding system by a feed arm where it is shredded.
  3. The shredded material is conveyed through a microwave section and temperature holding section, respectively for sterilization, with microwave of 2450MHz (±50MHz), temperature ≥95℃, with over 45minutes. (High pressure High temperature special type MDU will be a slightly different.)
  4. The sterilized and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor.
  5. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.
How does the Medical Waste Microwave Sterilization Unit (MDU) perform microwave sterilization?

Microwave sterilization is the result of microwave thermal effect and biological effect, which can make microwave energy and bacteria directly interact, rapid sterilization.

The thermal effect of microwave energy: Under certain intensity microwave field, the bacteria will be due to the absorption of polarized molecules can increase the temperature of microwave, so that the protein deformation, loss of biological activity. The thermal effect of microwave mainly plays the role of rapid temperature sterilization.

Non-thermal effects of microwave energy: High-frequency electric fields change the polarized molecular structure, resulting in the loss of vitality or death of proteins and physiologically active substances in the microbes, and the special effects of conventional physical sterilization in the sterilization

Applicable Range
  • Blood and Blood Products
  • Dialysis Waste
  • Animal Tissues, Body Parts, and Carcasses
  • Human Tissues, Body Parts, and Limbs
  • Biological and Non-Hazardous Pharmaceutical
  • Needles, Syringes, and other Sharps
  • Research Waste
  • Laboratory Specimens
  • Surgery Waste
  • Pathology and Histology Samples
  • Aids and Hepatitis Waste
  • Isolation Waste
  • Cultures and Slides
  • Intravenous Bags, Blood Bags, and Associated Tubing
  • Animal Bedding
  • Packaging Materials
  • Gloves, and Gowns Associated with Waste Collection
  • Trace Chemotherapy/anti- neo plastic waste
Technical Characteristics
  • 01 Energy saving

    Microwave heating is uniform, no energy loss, high energy, strong penetration into the object, instantaneous penetration into the object, good energy-saving effect, take the model with a daily processing capacity of 5T/d as an example, installed power Only 117 kilowatts.

  • 02 Efficient energy

    The temperature of action is low, and the heat loss is slow: If microwave and ordinary heating produce the same amount of sterilization, the temperature of the object will be significantly lower than that of ordinary heating. The waste after microwave sterilization is non-toxic, without residue, and lightly damaged.

  • 03 Absolute sterilization and disinfection

    Microwave can effectively sterilize all materials on all organisms with no select. It has a broad spectrum of sterilization bacteria and can kill various microorganisms and pathogens.

  • 04 Spatial convenience

    Microwave sterilization requires a small working environment and small area, does not cause high temperature to the surrounding environment, and is clean and hygienic.

  • 05 Environmental friendly

    No acid gas and dioxins and other pollutants are produced.

Equipment Advantages
  • The equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.
  • Low energy consumption, the whole set of equipment only needs electric drive, taking 5t per day as an example, the total installed power is only 117 kilowatts.
  • The medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.
  • There are two types of microwave sterilization equipment: fixed and mobile.
Technical Compare
Compare technologies LiYing Technology Autoclave Autoclave with a shedder Incinerator
  (Microwave) (Hot steam) (Hot steam) (Incineration)
Continuous process X X X
Integral shredding X X
Unrecognisable waste X
Volume of waste reduction X
Mass of waste reduction X X
Installation requirements Low High High High
Complexity of the installation Low Intermediate Intermediate High
On-site installable X
Technology approval by countries all over the world High Intermediate High Low
Level of sterelization High Intermediate High High
Odours Low High Intermediate Intermediate
Noise Low Intermediate Intermediate High
Treatment of pathological and anatomical waste X
Cost
ROI High Low Low Low
Investment costs Intermediate Low Intermediate High
Operating costs Low High High High
Maintenance costs Low High High High
Labour costs Low High High High
Environment
Impacts on the environment Low Intermediate Intermediate High
Treated waste recyclable X X X
No contaminated rejection (such as water, steam) X X X
Security
No risk related to pressurized vessel X X X
Risk for workforce/personnel health No risk of toxic contaminants released into the air or the treated waste Intermediate Intermediate High