logo
Products
PRODUCTS DETAILS
Home > Products >
Hospital Medical Waste Disposal Vehicle Truck 300kg/H 120kw

Hospital Medical Waste Disposal Vehicle Truck 300kg/H 120kw

MOQ: 1
Delivery Period: 45 work days
Payment Method: ,L/C,T/T
Supply Capacity: 10 units monthly
Detail Information
Place of Origin
CHINA
Brand Name
Li-Ying Technology
Certification
CE, ISO
Model Number
LYC-5150
Model No.:
LYC-5150
LYC5150XXDF6:
Non Specialized Operator : 2
Dimensions (L*W*H):
9780*2550*3990mm
Overall Weight:
15,000kg
Height When Flap Open:
6,500mm
Vehicle Mounted Generator:
-
Installed Power:
120kw (72kw Steam Generator Included)
Treatment Capacity (medical Waste Density Average 0.1kg/l~0.15kg/l):
300kg/h (±10%)
Operation And Control:
PLC Control, Automatic Process
Shredding System:
Two-shaft Shredder, Automatic Reverse System Is Configured To Avoid Material Blockage.
Feeding Form:
Automatic Lifting And Charging System Contained
Sterilization Temperature:
≥95℃
Sterilization Duration:
≥45min
Sterilization Effect:
≥6 Log10 (99.9999%) The Treatment Effect Test Uses Bacillus Subtilis Var. Niger Spore (ATCC 9372) As Biological Indicator, With Killing Logarithm Value ≥ 6.00.
Microwave Frequency:
2450MHz (±50MHz)
Microwave Generator Power:
1.25KW * 10unit
Disposal Staffing Needs:
Non Specialized Operator : 2
Highlight:

300kg/H Medical Waste Disposal Vehicle

,

120kw Medical Waste Disposal Vehicle

,

Hospital stericycle truck

Product Description
MDV series: Medical Waste Disposal Vehicle

The Medical Waste Disposal Vehicle (LiYing MDV) is a mobile sterilization station on a truck with an improved internal layout designed for mobile requirements. It adapts to various emergencies and support needs. Solid and efficient, and we have upgraded it for many generations to cope with the various situations and cases, so please contact us about detail.

Specifications:
  • Treatment capacity: up to 300kg/h (±10%)
  • Plug and Play
  • Optional generator
  • Integrated Sterilizer, Loader with Shredder
Introduction

The Medical Waste Disposal Vehicle (LiYing MDV series) is a mobile sterilization station on a truck with an improved internal layout designed for mobile requirements. It adapts to various emergencies and support needs. Solid and efficient, and we have upgraded it for many generations to cope with the hundreds of various situations and cases we meet, so please contact us about detail.

The convenience and flexibility of the mobile medical waste microwave sterilization vehicle make it a good service for various emergencies, which is plug and play, convenient and fast. It usualy well service for nature disasters like sudden epidemics and remote areas, and also military field hospital, marine and island medical waste disposal, etc.

The Medical waste Disposal Vehicle series treatment capaticy varies from 60kg/h to 300kg/h.

  • Rapid deployment, Plug and play!
  • Energy saving : Half the energy cost of autoclaves
  • Personnel-friendly and environmentally protective: below dioxin-producing temperatures
  • Effective: Microbial inactivation 99.9999% (6log10) .

Li-Ying-MDV-medical-waste-vehicle-workingLi-Ying MDV working

Specifications
  LYC-5150 LYC-5180
Model No. LYC5150XXDF6 LYC5180XXDS6
Dimensions (L*W*H) 9780*2550*3990mm 10150*2550*3990mm
Overall weight 15,000kg 18,000kg
Height when flap open 6,500mm 6,500mm
Vehicle mounted generator - 150kw
Installed Power 120kw (72kw steam generator included) 120kw (72kw steam generator included)
Treatment capacity (medical waste density average 0.1kg/l~0.15kg/l) 300kg/h (±10%)  300kg/h (±10%) 
Operation and control PLC control, automatic process
Shredding system Two-shaft shredder, automatic reverse system is configured to avoid material blockage.
Feeding form Automatic lifting and charging system contained
Sterilization temperature ≥95℃
Sterilization duration ≥45min
Sterilization effect ≥6 log10 (99.9999%) The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 6.00.
Microwave frequency 2450MHz (±50MHz)
Microwave generator power 1.25KW * 10unit
Disposal Staffing needs Non specialized operator : 2
Process
  1. Infectious waste is temporarily held in a waste container(s) and then emptied into a pre-storage hopper via a loading system located at the rear of the MDV.
  2. The infectious waste is fed into the shredding system by a feed arm where it is shredded.
  3. The shredded material is conveyed through a microwave section and temperature holding section, respectively for sterilization, with microwave of 2450MHz (±50MHz), temperature ≥95℃, with over 45 minutes.
  4. The sterilized and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor.
  5. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.
What does the Microwave Disposal Unit for Medical Waste do to bacteria?

Microwave sterilization is the result of microwave thermal effect and biological effect, which can make microwave energy and bacteria directly interact, rapid sterilization.

The thermal effect of microwave energy: Under certain intensity microwave field, the bacteria will be due to the absorption of polarized molecules can increase the temperature of microwave, so that the protein deformation, loss of biological activity. The thermal effect of microwave mainly plays the role of rapid temperature sterilization.

Non-thermal effects of microwave energy: High-frequency electric fields change the polarized molecular structure, resulting in the loss of vitality or death of proteins and physiologically active substances in the microbes, and the special effects of conventional physical sterilization in the sterilization

Applicable Range
  • Blood and Blood Products
  • Dialysis Waste
  • Animal Tissues, Body Parts, and Carcasses
  • Human Tissues, Body Parts, and Limbs
  • Biological and Non-Hazardous Pharmaceutical
  • Needles, Syringes, and other Sharps
  • Research Waste
  • Laboratory Specimens
  • Surgery Waste
  • Pathology and Histology Samples
  • Aids and Hepatitis Waste
  • Isolation Waste
  • Cultures and Slides
  • Intravenous Bags, Blood Bags, and Associated Tubing
  • Animal Bedding
  • Packaging Materials
  • Gloves, and Gowns Associated with Waste Collection
  • Trace Chemotherapy/anti- neo plastic waste
Technical Characteristics

MDU series products are designed as an automatic operation system with minimal operator operations, with the following characteristics:

  1. Energy saving

    Microwave heating is uniform, no energy loss, high energy, strong penetration into the object, instantaneous penetration into the object, good energy-saving effect, take the model with a daily processing capacity of 5T/d as an example, installed power Only 117 kilowatts.

  2. Efficient energy

    The temperature of action is low, and the heat loss is slow: If microwave and ordinary heating produce the same amount of sterilization, the temperature of the object will be significantly lower than that of ordinary heating. The waste after microwave sterilization is non-toxic, without residue, and lightly damaged.

  3. Absolute sterilization and disinfection

    Microwave can effectively sterilize all materials on all organisms with no select. It has a broad spectrum of sterilization bacteria and can kill various microorganisms and pathogens.

  4. Spatial convenience

    Microwave sterilization requires a small working environment and small area, does not cause high temperature to the surrounding environment, and is clean and hygienic.

  5. Environmental friendly

    No acid gas and dioxins and other pollutants are produced.

Equipment Advantages
  • Integrated equipment design, convenient and fast, with low operation noise.
  • The equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.
  • Low energy consumption, the whole set of equipment only needs only electric drive.
  • The medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.
  • The convenience and flexibility of the mobile medical waste microwave sterilization vehicle make it a good service for various emergencies.
  • For areas with vast land and sparsely populated areas where the amount of medical waste generated is small, one vehicle can serve multiple areas.
Technical Compare
Compare technologies LiYing Tech Autoclave Incinerator
  (Microwave) (Hot steam) (Incineration)
Process Continuous/Batch Batch Continuous/Batch
Integral shredding X X
Waste volume reduced
Installation requirements Low High Very High
On-site installable X
Odor Low High High
Noise Low High High
Sterilization effect High High High
Cost      
Labor costs Low High High
Investment costs Intermediate Intermediate High
Energy Used Very Low High High
Maintenance costs Low High High
ROI High Low Low
Features      
Environmental Impact Eco-friendly Intermediate Significant
Safety High Pressure risk Low
Ease of Operation One-man Operation Low Low
Products
PRODUCTS DETAILS
Hospital Medical Waste Disposal Vehicle Truck 300kg/H 120kw
MOQ: 1
Delivery Period: 45 work days
Payment Method: ,L/C,T/T
Supply Capacity: 10 units monthly
Detail Information
Place of Origin
CHINA
Brand Name
Li-Ying Technology
Certification
CE, ISO
Model Number
LYC-5150
Model No.:
LYC-5150
LYC5150XXDF6:
Non Specialized Operator : 2
Dimensions (L*W*H):
9780*2550*3990mm
Overall Weight:
15,000kg
Height When Flap Open:
6,500mm
Vehicle Mounted Generator:
-
Installed Power:
120kw (72kw Steam Generator Included)
Treatment Capacity (medical Waste Density Average 0.1kg/l~0.15kg/l):
300kg/h (±10%)
Operation And Control:
PLC Control, Automatic Process
Shredding System:
Two-shaft Shredder, Automatic Reverse System Is Configured To Avoid Material Blockage.
Feeding Form:
Automatic Lifting And Charging System Contained
Sterilization Temperature:
≥95℃
Sterilization Duration:
≥45min
Sterilization Effect:
≥6 Log10 (99.9999%) The Treatment Effect Test Uses Bacillus Subtilis Var. Niger Spore (ATCC 9372) As Biological Indicator, With Killing Logarithm Value ≥ 6.00.
Microwave Frequency:
2450MHz (±50MHz)
Microwave Generator Power:
1.25KW * 10unit
Disposal Staffing Needs:
Non Specialized Operator : 2
Minimum Order Quantity:
1
Delivery Time:
45 work days
Payment Terms:
,L/C,T/T
Supply Ability:
10 units monthly
Highlight

300kg/H Medical Waste Disposal Vehicle

,

120kw Medical Waste Disposal Vehicle

,

Hospital stericycle truck

Product Description
MDV series: Medical Waste Disposal Vehicle

The Medical Waste Disposal Vehicle (LiYing MDV) is a mobile sterilization station on a truck with an improved internal layout designed for mobile requirements. It adapts to various emergencies and support needs. Solid and efficient, and we have upgraded it for many generations to cope with the various situations and cases, so please contact us about detail.

Specifications:
  • Treatment capacity: up to 300kg/h (±10%)
  • Plug and Play
  • Optional generator
  • Integrated Sterilizer, Loader with Shredder
Introduction

The Medical Waste Disposal Vehicle (LiYing MDV series) is a mobile sterilization station on a truck with an improved internal layout designed for mobile requirements. It adapts to various emergencies and support needs. Solid and efficient, and we have upgraded it for many generations to cope with the hundreds of various situations and cases we meet, so please contact us about detail.

The convenience and flexibility of the mobile medical waste microwave sterilization vehicle make it a good service for various emergencies, which is plug and play, convenient and fast. It usualy well service for nature disasters like sudden epidemics and remote areas, and also military field hospital, marine and island medical waste disposal, etc.

The Medical waste Disposal Vehicle series treatment capaticy varies from 60kg/h to 300kg/h.

  • Rapid deployment, Plug and play!
  • Energy saving : Half the energy cost of autoclaves
  • Personnel-friendly and environmentally protective: below dioxin-producing temperatures
  • Effective: Microbial inactivation 99.9999% (6log10) .

Li-Ying-MDV-medical-waste-vehicle-workingLi-Ying MDV working

Specifications
  LYC-5150 LYC-5180
Model No. LYC5150XXDF6 LYC5180XXDS6
Dimensions (L*W*H) 9780*2550*3990mm 10150*2550*3990mm
Overall weight 15,000kg 18,000kg
Height when flap open 6,500mm 6,500mm
Vehicle mounted generator - 150kw
Installed Power 120kw (72kw steam generator included) 120kw (72kw steam generator included)
Treatment capacity (medical waste density average 0.1kg/l~0.15kg/l) 300kg/h (±10%)  300kg/h (±10%) 
Operation and control PLC control, automatic process
Shredding system Two-shaft shredder, automatic reverse system is configured to avoid material blockage.
Feeding form Automatic lifting and charging system contained
Sterilization temperature ≥95℃
Sterilization duration ≥45min
Sterilization effect ≥6 log10 (99.9999%) The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 6.00.
Microwave frequency 2450MHz (±50MHz)
Microwave generator power 1.25KW * 10unit
Disposal Staffing needs Non specialized operator : 2
Process
  1. Infectious waste is temporarily held in a waste container(s) and then emptied into a pre-storage hopper via a loading system located at the rear of the MDV.
  2. The infectious waste is fed into the shredding system by a feed arm where it is shredded.
  3. The shredded material is conveyed through a microwave section and temperature holding section, respectively for sterilization, with microwave of 2450MHz (±50MHz), temperature ≥95℃, with over 45 minutes.
  4. The sterilized and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor.
  5. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.
What does the Microwave Disposal Unit for Medical Waste do to bacteria?

Microwave sterilization is the result of microwave thermal effect and biological effect, which can make microwave energy and bacteria directly interact, rapid sterilization.

The thermal effect of microwave energy: Under certain intensity microwave field, the bacteria will be due to the absorption of polarized molecules can increase the temperature of microwave, so that the protein deformation, loss of biological activity. The thermal effect of microwave mainly plays the role of rapid temperature sterilization.

Non-thermal effects of microwave energy: High-frequency electric fields change the polarized molecular structure, resulting in the loss of vitality or death of proteins and physiologically active substances in the microbes, and the special effects of conventional physical sterilization in the sterilization

Applicable Range
  • Blood and Blood Products
  • Dialysis Waste
  • Animal Tissues, Body Parts, and Carcasses
  • Human Tissues, Body Parts, and Limbs
  • Biological and Non-Hazardous Pharmaceutical
  • Needles, Syringes, and other Sharps
  • Research Waste
  • Laboratory Specimens
  • Surgery Waste
  • Pathology and Histology Samples
  • Aids and Hepatitis Waste
  • Isolation Waste
  • Cultures and Slides
  • Intravenous Bags, Blood Bags, and Associated Tubing
  • Animal Bedding
  • Packaging Materials
  • Gloves, and Gowns Associated with Waste Collection
  • Trace Chemotherapy/anti- neo plastic waste
Technical Characteristics

MDU series products are designed as an automatic operation system with minimal operator operations, with the following characteristics:

  1. Energy saving

    Microwave heating is uniform, no energy loss, high energy, strong penetration into the object, instantaneous penetration into the object, good energy-saving effect, take the model with a daily processing capacity of 5T/d as an example, installed power Only 117 kilowatts.

  2. Efficient energy

    The temperature of action is low, and the heat loss is slow: If microwave and ordinary heating produce the same amount of sterilization, the temperature of the object will be significantly lower than that of ordinary heating. The waste after microwave sterilization is non-toxic, without residue, and lightly damaged.

  3. Absolute sterilization and disinfection

    Microwave can effectively sterilize all materials on all organisms with no select. It has a broad spectrum of sterilization bacteria and can kill various microorganisms and pathogens.

  4. Spatial convenience

    Microwave sterilization requires a small working environment and small area, does not cause high temperature to the surrounding environment, and is clean and hygienic.

  5. Environmental friendly

    No acid gas and dioxins and other pollutants are produced.

Equipment Advantages
  • Integrated equipment design, convenient and fast, with low operation noise.
  • The equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.
  • Low energy consumption, the whole set of equipment only needs only electric drive.
  • The medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.
  • The convenience and flexibility of the mobile medical waste microwave sterilization vehicle make it a good service for various emergencies.
  • For areas with vast land and sparsely populated areas where the amount of medical waste generated is small, one vehicle can serve multiple areas.
Technical Compare
Compare technologies LiYing Tech Autoclave Incinerator
  (Microwave) (Hot steam) (Incineration)
Process Continuous/Batch Batch Continuous/Batch
Integral shredding X X
Waste volume reduced
Installation requirements Low High Very High
On-site installable X
Odor Low High High
Noise Low High High
Sterilization effect High High High
Cost      
Labor costs Low High High
Investment costs Intermediate Intermediate High
Energy Used Very Low High High
Maintenance costs Low High High
ROI High Low Low
Features      
Environmental Impact Eco-friendly Intermediate Significant
Safety High Pressure risk Low
Ease of Operation One-man Operation Low Low