| MOQ: | 30 |
| Delivery Period: | 45 work days |
| Payment Method: | L/C,T/T |
| Supply Capacity: | 500 units monthly |
It’s a sterilizer that uses the dual effects of microwave and high-pressure steam to sterilize biohazardous Waste.
Treatment capacity appr. 2kg/hr. Perfectly suited for disposing of medical waste in medium or small sized hospitals, clinics or any health centre, Customs and Quarantine Departments, etc.
Treatment capacity: 17L/cycle, or appr. 2 kg/hr (±10%)
On-site medical waste disposal equipment for hospitals and clinics
Is a Microwave Medical Waste Disposal Unit that uses the dual effects of microwave and high pressure steam to sterilize Regulated Medical Waste (RMW), or medical waste with infection risk.
Treatment capacity: appr. 2kg/hr (based on an average density of medical waste at 0.1kg/l ~0.15kg/l.)
Sterilization bin volume: 30L
The disposal unit first introduces high-pressure saturated steam into the high-pressure disinfection chamber of medical waste, while starting a microwave generator. It uses the thermal effect of microwave to heat the high-pressure disinfection chamber to maintain temperature and prevent steam condensation. It is sterilized by the sensitivity of bacteria to temperature. In addition, microwave has a non-thermal effect, Non thermal effect refers to other microbial killing effects besides thermal effect, which is a unique effect of microwave sterilization. The heating and warming process of the equipment is also a disinfection process. After the disinfection chamber reaches 135 ℃ or above, it is held for another 5 minutes to complete the disinfection.
High disinfection efficiency : 99.9999% sterilization in 5 minutes under the temperature and pressure conditions achieved.
Energy saving : Half the energy cost of autoclaves
Personnel-friendly & Eco: Below dioxin generation temperature
| Model. | MMDU-30 |
| Main unit body Dimensions | 634mm*503mm*749mm |
| Overall weight | 110kg |
| Treatment type | High temperature steam and Microwave sterilization |
| Type of process | Semi-automatic process |
| Chamber volume | 30 Liter |
| Control | Simple button operation |
| Sterilization temperature | ≥ 135℃ |
| Pressure | ≥ 0.33MPa |
| Sterilization cycle | ≥ 30 minutes |
| Installed power | 3.5 Kw |
| Utility Requirements | Electricity: 220V |
| Treatment capacity * | 17L/cycle, or appr. 2 kg/hr (±10%) |
| Staff requirements | No specialized operator / 1 operator |
| Exhaust gas treatment system | Included |
| Disposal section material | 304 stainless steel |
| Microwave frequency | 2450 +/- 50 MHz |
| Microwave generator power | 1.25kW |
| Treatment effect | 6 log 10. The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 6.00. |
| With a 'parameter printer' built into the machine that can track cycle data such as hospital name/operator name/cycle time/weight/cycle status. | |
The processing scope of the equipment includes infectious, injurious, and pathological waste in the category of Biohazardous Waste.
*Do not put containers in a sealed state into the equipment.
High pressure steam and microwave combination disinfection, the disinfection process only takes 5 minutes, high disinfection efficiency, energy saving;
Using a water cooled microwave generator, the cooling medium is antifreeze, with a long service life;
The door of the microwave disinfection equipment adopts a conductive sealing strip sealing structure and is equipped with an interlocking system to prevent microwave leakage;
The disinfection chamber is made of 304 stainless steel, it is durable.
Equipped with an exhaust gas treatment device, including a high-efficiency filter and an activated carbon filter, the high-efficiency filter is used to treat microorganisms contained in the exhaust gas, with a filter particle diameter of 0.2 μ m. It can filter out almost all microorganisms, and activated carbon filters are used for deodorization.
| Compare technologies | LiYing Technology | Autoclave | Autoclave with a shedder | Incinerator |
|---|---|---|---|---|
| (Microwave) | (Hot steam) | (Hot steam) | (Incineration) | |
| Continuous process | ✓ | X | X | X |
| Integral shredding | ✓ | X | ✓ | X |
| Unrecognisable waste | ✓ | X | ✓ | ✓ |
| Volume of waste reduction | ✓ | X | ✓ | ✓ |
| Mass of waste reduction | ✓ | X | X | ✓ |
| Installation requirements | Low | High | High | High |
| Complexity of the installation | Low | Intermediate | Intermediate | High |
| On-site installable | ✓ | ✓ | ✓ | X |
| Technology approval by countries all over the world | High | Intermediate | High | Low |
| Level of sterelization | High | Intermediate | High | High |
| Odours | Low | High | Intermediate | Intermediate |
| Noise | Low | Intermediate | Intermediate | High |
| Treatment of pathological and anatomical waste | ✓ | X | ✓ | ✓ |
| Cost | ||||
| ROI | High | Low | Low | Low |
| Investment costs | Intermediate | Low | Intermediate | High |
| Operating costs | Low | High | High | High |
| Maintenance costs | Low | High | High | High |
| Labour costs | Low | High | High | High |
| Environment | ||||
| Impacts on the environment | Low | Intermediate | Intermediate | High |
| Treated waste recyclable | ✓ | X | X | X |
| No contaminated rejection (such as water, steam) | ✓ | X | X | X |
| Security | ||||
| No risk related to pressurized vessel | ✓ | X | X | X |
| Risk for workforce/personnel health | No risk of toxic contaminants released into the air or the treated waste | Intermediate | Intermediate | High |
| MOQ: | 30 |
| Delivery Period: | 45 work days |
| Payment Method: | L/C,T/T |
| Supply Capacity: | 500 units monthly |
It’s a sterilizer that uses the dual effects of microwave and high-pressure steam to sterilize biohazardous Waste.
Treatment capacity appr. 2kg/hr. Perfectly suited for disposing of medical waste in medium or small sized hospitals, clinics or any health centre, Customs and Quarantine Departments, etc.
Treatment capacity: 17L/cycle, or appr. 2 kg/hr (±10%)
On-site medical waste disposal equipment for hospitals and clinics
Is a Microwave Medical Waste Disposal Unit that uses the dual effects of microwave and high pressure steam to sterilize Regulated Medical Waste (RMW), or medical waste with infection risk.
Treatment capacity: appr. 2kg/hr (based on an average density of medical waste at 0.1kg/l ~0.15kg/l.)
Sterilization bin volume: 30L
The disposal unit first introduces high-pressure saturated steam into the high-pressure disinfection chamber of medical waste, while starting a microwave generator. It uses the thermal effect of microwave to heat the high-pressure disinfection chamber to maintain temperature and prevent steam condensation. It is sterilized by the sensitivity of bacteria to temperature. In addition, microwave has a non-thermal effect, Non thermal effect refers to other microbial killing effects besides thermal effect, which is a unique effect of microwave sterilization. The heating and warming process of the equipment is also a disinfection process. After the disinfection chamber reaches 135 ℃ or above, it is held for another 5 minutes to complete the disinfection.
High disinfection efficiency : 99.9999% sterilization in 5 minutes under the temperature and pressure conditions achieved.
Energy saving : Half the energy cost of autoclaves
Personnel-friendly & Eco: Below dioxin generation temperature
| Model. | MMDU-30 |
| Main unit body Dimensions | 634mm*503mm*749mm |
| Overall weight | 110kg |
| Treatment type | High temperature steam and Microwave sterilization |
| Type of process | Semi-automatic process |
| Chamber volume | 30 Liter |
| Control | Simple button operation |
| Sterilization temperature | ≥ 135℃ |
| Pressure | ≥ 0.33MPa |
| Sterilization cycle | ≥ 30 minutes |
| Installed power | 3.5 Kw |
| Utility Requirements | Electricity: 220V |
| Treatment capacity * | 17L/cycle, or appr. 2 kg/hr (±10%) |
| Staff requirements | No specialized operator / 1 operator |
| Exhaust gas treatment system | Included |
| Disposal section material | 304 stainless steel |
| Microwave frequency | 2450 +/- 50 MHz |
| Microwave generator power | 1.25kW |
| Treatment effect | 6 log 10. The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 6.00. |
| With a 'parameter printer' built into the machine that can track cycle data such as hospital name/operator name/cycle time/weight/cycle status. | |
The processing scope of the equipment includes infectious, injurious, and pathological waste in the category of Biohazardous Waste.
*Do not put containers in a sealed state into the equipment.
High pressure steam and microwave combination disinfection, the disinfection process only takes 5 minutes, high disinfection efficiency, energy saving;
Using a water cooled microwave generator, the cooling medium is antifreeze, with a long service life;
The door of the microwave disinfection equipment adopts a conductive sealing strip sealing structure and is equipped with an interlocking system to prevent microwave leakage;
The disinfection chamber is made of 304 stainless steel, it is durable.
Equipped with an exhaust gas treatment device, including a high-efficiency filter and an activated carbon filter, the high-efficiency filter is used to treat microorganisms contained in the exhaust gas, with a filter particle diameter of 0.2 μ m. It can filter out almost all microorganisms, and activated carbon filters are used for deodorization.
| Compare technologies | LiYing Technology | Autoclave | Autoclave with a shedder | Incinerator |
|---|---|---|---|---|
| (Microwave) | (Hot steam) | (Hot steam) | (Incineration) | |
| Continuous process | ✓ | X | X | X |
| Integral shredding | ✓ | X | ✓ | X |
| Unrecognisable waste | ✓ | X | ✓ | ✓ |
| Volume of waste reduction | ✓ | X | ✓ | ✓ |
| Mass of waste reduction | ✓ | X | X | ✓ |
| Installation requirements | Low | High | High | High |
| Complexity of the installation | Low | Intermediate | Intermediate | High |
| On-site installable | ✓ | ✓ | ✓ | X |
| Technology approval by countries all over the world | High | Intermediate | High | Low |
| Level of sterelization | High | Intermediate | High | High |
| Odours | Low | High | Intermediate | Intermediate |
| Noise | Low | Intermediate | Intermediate | High |
| Treatment of pathological and anatomical waste | ✓ | X | ✓ | ✓ |
| Cost | ||||
| ROI | High | Low | Low | Low |
| Investment costs | Intermediate | Low | Intermediate | High |
| Operating costs | Low | High | High | High |
| Maintenance costs | Low | High | High | High |
| Labour costs | Low | High | High | High |
| Environment | ||||
| Impacts on the environment | Low | Intermediate | Intermediate | High |
| Treated waste recyclable | ✓ | X | X | X |
| No contaminated rejection (such as water, steam) | ✓ | X | X | X |
| Security | ||||
| No risk related to pressurized vessel | ✓ | X | X | X |
| Risk for workforce/personnel health | No risk of toxic contaminants released into the air or the treated waste | Intermediate | Intermediate | High |