Three Phase On Site Medical Waste Treatment Equipment Industry Disposal Unit 52KW 380V

MOQ: 1
Delivery Period: 45 work days
Payment Method: L/C,T/T
Supply Capacity: 10 units monthly
Detail Information
Place of Origin
CHINA
Brand Name
Li-Ying Technology
Certification
ISO
Model Number
SSE-100
Model:
SSE-100
Processing Capacity:
25 Kg/cycle, 50 Kg/hr
SSE-75(Unreleased Yet):
3.5t
Power:
52Kw
Dimensions (L*W*H):
556cm*202cm*200cm
Treatment Type:
High Temperature Steam And Microwave Sterilization
Sterilization Effect:
Log6 (Bacillus Subtilis Var. Niger, ATCC9372)
Power Supply:
Three Phase Five Wire AC380V
Working Pressure::
-0.09~0.24MPa
Sterilization Temperature:
134℃~138℃
Sterilization Cycle:
30min
Weight:
6.5t
Highlight:

380V Medical Waste Treatment Equipment

,

52KW Medical Waste Treatment Equipment

,

380V medical waste management industry

Product Description
SSE-100

The serie SSE-100 medwaste disposal equipment for hospital is our 2024 new treatment system that utilizes high-temperature steam and microwave to disinfect medical waste; The process of steam+microwave treatment followed by shredding treatment, including process units such as “feeding, pre vacuum, high-temperature steam treatment, drying, discharge, and shredding".

Key Features
  • Processing capacity: 25 kg/cycle or 50 kg/hour
  • Eco-friendly and Energy Saving
  • Sterilization Temperature: 134°C~138°C
  • Low cost still top efficient
Introduction

The SSE-100 is Li-Ying's new fully automated medical waste treatment system that uses high temperature high pressure steam and microwave to sterilize Regulated Medical Waste (RMW), namely medical waste with infection risk. Using a process of disposal followed by shredding. Integrated built-in process units including "pre-vacuum, steam and microwave combined treatment, drying, discharging and shredding".

  • Treatment capacity 50 kg/hr.
  • One-man operation
  • No dioxin emissions
  • Perfectly suited for disposing of medical waste in large or medium sized hospitals, clinics or any health centre, Customs and Quarantine Departments, etc.
Specifications
ModelSSE-100SSE-75 (Unreleased yet)
Processing capacity25 kg/cycle, 50 kg/hr15 kg/cycle, 30 kg/hr
Power52Kw36Kw
Dimensions (L*W*H)556cm*202cm*200cm430cm*180cm*175cm
Treatment typeHigh temperature steam and Microwave sterilization
Sterilization effectlog6 (Bacillus subtilis var. niger, ATCC9372)
Power supplyThree phase five wire AC380V
Working Pressure:-0.09~0.24MPa
Sterilization temperature134℃~138℃
Sterilization Cycle30min
Weight6.5t3.5t
Standard Configuration
  • High temperature steam and microwave combined sterilization system
  • (including steam generator and microwave generator)
  • Built-in shredder
  • Exhaust gas treatment system
  • Water purification system
  • Microwave leak detector (networking)
  • PLC control system with screen
Optional Configuration
  • Automatic Feeding Unit
  • And more OEMs, ODMs.
Technical principle

The principle of the pressure steam sterilisation process is the penetration of pressurised steam into the interior of an object. It causes microbial proteins to coagulate, denature and die, and it enhances the efficiency of microwave sterilisation. The treated medical waste is sent to sanitary landfills or incinerated. This method is also suitable for sterilising contaminated overalls, syringes, dressings, microbiological media, etc.

Process
  1. The SSE-100 treatment process includes medical waste feeding, high-temperature steam sterilization ,Drying, Shredding, Unloading with Wastewater and exhaust gas treatment.
  2. Feeding, the operator loads the medical waste into the hopper and then enters the automatic disposal process. (Automatic Feeding Optional for SSE)
  3. Steam and microwave sterilization, in this process, a preset pressure and temperature are first achieved through a heating procedure for sterilization. In the heat preservation stage, the waste is kept above the preset temperature and maintained for sufficient time to ensure sterilization effect. Steam is discharged through a pressure relief procedure.
  4. Drying and Shredding, Through the drying process, part of the water is removed from the waste to ensure that the waste reaches a completely sterile state. After treatment, the medical waste should be decontaminated and unrecognizable.
  5. Post-treatment, the completion of these procedures will ensure that clinical waste is thoroughly sterilised, and the waste gas generated during the disposal process is collected by negative pressure fans and processed by the waste gas treatment system to protect the environment and public health and safety.
  6. Discharge, the sterilised and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.
Applicable Range
  • Blood and Blood Products
  • Dialysis Waste
  • Animal Tissues, Body Parts, and Carcasses
  • Human Tissues, Body Parts, and Limbs
  • Biological and Non-Hazardous Pharmaceutical
  • Needles, Syringes, and other Sharps
  • Research Waste
  • Laboratory Specimens
  • Surgery Waste
  • Pathology and Histology Samples
  • Aids and Hepatitis Waste
  • Isolation Waste
  • Cultures and Slides
  • Intravenous Bags, Blood Bags, and Associated Tubing
  • Animal Bedding
  • Packaging Materials
  • Gloves, and Gowns Associated with Waste Collection
  • Trace Chemotherapy/anti- neo plastic waste
Equipment Advantages
  • Easy transportation and installation with an integrated design.
  • High degree of automation, single person operation, after the medical waste being poured into the hopper, the equipment automatically completes whole procedures of medical waste treatment
  • Low cost still top efficient. Low water content in the treated medical waste, because of a vacuum drying technology.
  • In whole processing of the sterilization of medical waste. shredding is a key procedure. Shredder of the MDU-SSE series equipment adopts a low speed, high torque dual drive hydraulic motor.
Recommended Products
Products
PRODUCTS DETAILS
Three Phase On Site Medical Waste Treatment Equipment Industry Disposal Unit 52KW 380V
MOQ: 1
Delivery Period: 45 work days
Payment Method: L/C,T/T
Supply Capacity: 10 units monthly
Detail Information
Place of Origin
CHINA
Brand Name
Li-Ying Technology
Certification
ISO
Model Number
SSE-100
Model:
SSE-100
Processing Capacity:
25 Kg/cycle, 50 Kg/hr
SSE-75(Unreleased Yet):
3.5t
Power:
52Kw
Dimensions (L*W*H):
556cm*202cm*200cm
Treatment Type:
High Temperature Steam And Microwave Sterilization
Sterilization Effect:
Log6 (Bacillus Subtilis Var. Niger, ATCC9372)
Power Supply:
Three Phase Five Wire AC380V
Working Pressure::
-0.09~0.24MPa
Sterilization Temperature:
134℃~138℃
Sterilization Cycle:
30min
Weight:
6.5t
Minimum Order Quantity:
1
Delivery Time:
45 work days
Payment Terms:
L/C,T/T
Supply Ability:
10 units monthly
Highlight

380V Medical Waste Treatment Equipment

,

52KW Medical Waste Treatment Equipment

,

380V medical waste management industry

Product Description
SSE-100

The serie SSE-100 medwaste disposal equipment for hospital is our 2024 new treatment system that utilizes high-temperature steam and microwave to disinfect medical waste; The process of steam+microwave treatment followed by shredding treatment, including process units such as “feeding, pre vacuum, high-temperature steam treatment, drying, discharge, and shredding".

Key Features
  • Processing capacity: 25 kg/cycle or 50 kg/hour
  • Eco-friendly and Energy Saving
  • Sterilization Temperature: 134°C~138°C
  • Low cost still top efficient
Introduction

The SSE-100 is Li-Ying's new fully automated medical waste treatment system that uses high temperature high pressure steam and microwave to sterilize Regulated Medical Waste (RMW), namely medical waste with infection risk. Using a process of disposal followed by shredding. Integrated built-in process units including "pre-vacuum, steam and microwave combined treatment, drying, discharging and shredding".

  • Treatment capacity 50 kg/hr.
  • One-man operation
  • No dioxin emissions
  • Perfectly suited for disposing of medical waste in large or medium sized hospitals, clinics or any health centre, Customs and Quarantine Departments, etc.
Specifications
ModelSSE-100SSE-75 (Unreleased yet)
Processing capacity25 kg/cycle, 50 kg/hr15 kg/cycle, 30 kg/hr
Power52Kw36Kw
Dimensions (L*W*H)556cm*202cm*200cm430cm*180cm*175cm
Treatment typeHigh temperature steam and Microwave sterilization
Sterilization effectlog6 (Bacillus subtilis var. niger, ATCC9372)
Power supplyThree phase five wire AC380V
Working Pressure:-0.09~0.24MPa
Sterilization temperature134℃~138℃
Sterilization Cycle30min
Weight6.5t3.5t
Standard Configuration
  • High temperature steam and microwave combined sterilization system
  • (including steam generator and microwave generator)
  • Built-in shredder
  • Exhaust gas treatment system
  • Water purification system
  • Microwave leak detector (networking)
  • PLC control system with screen
Optional Configuration
  • Automatic Feeding Unit
  • And more OEMs, ODMs.
Technical principle

The principle of the pressure steam sterilisation process is the penetration of pressurised steam into the interior of an object. It causes microbial proteins to coagulate, denature and die, and it enhances the efficiency of microwave sterilisation. The treated medical waste is sent to sanitary landfills or incinerated. This method is also suitable for sterilising contaminated overalls, syringes, dressings, microbiological media, etc.

Process
  1. The SSE-100 treatment process includes medical waste feeding, high-temperature steam sterilization ,Drying, Shredding, Unloading with Wastewater and exhaust gas treatment.
  2. Feeding, the operator loads the medical waste into the hopper and then enters the automatic disposal process. (Automatic Feeding Optional for SSE)
  3. Steam and microwave sterilization, in this process, a preset pressure and temperature are first achieved through a heating procedure for sterilization. In the heat preservation stage, the waste is kept above the preset temperature and maintained for sufficient time to ensure sterilization effect. Steam is discharged through a pressure relief procedure.
  4. Drying and Shredding, Through the drying process, part of the water is removed from the waste to ensure that the waste reaches a completely sterile state. After treatment, the medical waste should be decontaminated and unrecognizable.
  5. Post-treatment, the completion of these procedures will ensure that clinical waste is thoroughly sterilised, and the waste gas generated during the disposal process is collected by negative pressure fans and processed by the waste gas treatment system to protect the environment and public health and safety.
  6. Discharge, the sterilised and unrecognizable (sharps) waste is then discharged into large waste containers (or compaction units) by the discharging screw conveyor. From there the material can be transported to a local municipal landfill for disposal or to a refuse recycling plant.
Applicable Range
  • Blood and Blood Products
  • Dialysis Waste
  • Animal Tissues, Body Parts, and Carcasses
  • Human Tissues, Body Parts, and Limbs
  • Biological and Non-Hazardous Pharmaceutical
  • Needles, Syringes, and other Sharps
  • Research Waste
  • Laboratory Specimens
  • Surgery Waste
  • Pathology and Histology Samples
  • Aids and Hepatitis Waste
  • Isolation Waste
  • Cultures and Slides
  • Intravenous Bags, Blood Bags, and Associated Tubing
  • Animal Bedding
  • Packaging Materials
  • Gloves, and Gowns Associated with Waste Collection
  • Trace Chemotherapy/anti- neo plastic waste
Equipment Advantages
  • Easy transportation and installation with an integrated design.
  • High degree of automation, single person operation, after the medical waste being poured into the hopper, the equipment automatically completes whole procedures of medical waste treatment
  • Low cost still top efficient. Low water content in the treated medical waste, because of a vacuum drying technology.
  • In whole processing of the sterilization of medical waste. shredding is a key procedure. Shredder of the MDU-SSE series equipment adopts a low speed, high torque dual drive hydraulic motor.